supermarket refrigerated showcase » article > display refrigerator > display cooler disassembly, diagnosis and maintenance of defrost heater
display cooler disassembly, diagnosis and maintenance of defrost heater

disassembly, diagnosis and maintenance of defrost heater
n9n The position of the non-detachable defrosting heater in the
display cooler, the defrosting heater and the evaporator winding together, the diameter of the defrosting heater is thick, the process is rough, generally there will be no problems, there is no disassembly, etc. So only the detachable defrost heater will be introduced below.
1. Disassembly and assembly of the defrost heater Unplug the
display cooler power plug > remove the freezer air duct grating > and find the arc under the evaporator The defrost heater under the aluminum plate is > the two hooks of the fixed heater are opened at an angle, and the defrost heater is taken out. Some models can take out the defrost heater without the fixed hook. Installation is the reverse process of disassembly. [Note] During the process of disassembling the defrosting heater, the round aluminum plate must not be damaged, otherwise the defrosting water will drip onto the defrosting heater, damaging the defrosting heater, and even burn out the inner tank of the display cooler. The carburetor must be installed in the original position, that is, on the suspended support under the national-shaped aluminum plate, and cannot be placed in the water receiving tank casually.
2. Defrost heater diagnosis and maintenance. Defrost heater wire damage is mostly open circuit, and the failure rate is high. The reason is mostly that the internal water is corroded. Only replace the heater of the same specification, otherwise it will cause no defrosting. The
display cooler has been used for two or three days to cool normally, and then the cooling effect will decrease. Find the two wiring plugs of the defrost heater and unplug it. You don't need to remove the defrost heater wire, and directly measure the resistance of the two plugs. The normal value should be 320Q-500Q. Infinity is an open circuit. For on-site maintenance without a multimeter, you can only remove the defrosting heating wire to observe the internal metal wire. If the inside is white or broken, it means it is damaged.
the above articles are from refrigerated showcase display cooler, display cooler prices, for details, please visit: www.ihdjx.com